Каталог Корзина0
| Оптические кабели SYSTIMAX

760231589 Кабель оптический LazrSPEED 550 WB, 12 волокон ОМ5, LSZH, внутренний, светло-зеленый, фут

Артикул: 760231589
Есть в наличии Цена по запросу Запросить цену Сравнить В сравнении

Доставка
при оплате сегодня (18.04.2024):

Москва:
— Самовывоз: завтра
— Курьером: 1 день

Регионы РФ
— ТК: 3-4 дня

Оплата
— Безналичный расчёт

Product Classification

Portfolio
CommScope
Product Type
Fiber indoor cable
Regional Availability
Asia,Australia/New Zealand,EMEA,Latin America,North America

Standards And Qualifications

EN50575 CPR Cable EuroClass
Dca,s1a,d1,a2
Cable Qualification Standards
ANSI/ICEA S-83-596,Telcordia GR-409

Representative Image

Click on image below to enlarge.

General Specifications

Cable Type
Distribution
Construction Type
Non-armored
Subunit Type
Gel-free

Construction Materials

Fiber Type Solution
OM5, LazrSPEED wideband
Total Fiber Count
12
Fiber Type
OM5, LazrSPEED wideband
Fiber Type, quantity
12
Jacket Color
Lime green

Dimensions

Cable Weight
22.8 lb/kft,34.0 kg/km
Diameter Over Jacket
6.07 mm,0.24 in

Physical Specifications

Minimum Bend Radius, loaded
9.1 cm,3.6 in
Minimum Bend Radius, unloaded
6.1 cm,2.4 in
Tensile Load, long term, maximum
45 lbf,200 N
Tensile Load, short term, maximum
150 lbf,667 N
Vertical Rise, maximum
500.0 m,1640.4 ft

Flame Test Specifications

Flame Test Listing
NEC OFNR-LS ETL and c ETL
Flame Test Method
IEC 60332-3,IEC 60754-2,IEC 61034-2,IEEE 383,UL 1666,UL 1685

Environmental Specifications

Environmental Space
Low Smoke Zero Halogen LSZH,Riser
Installation Temperature
-10 C to 60 C 14 F to 140 F
Operating Temperature
-20 C to 70 C -4 F to 158 F
Storage Temperature
-40 C to 70 C -40 F to 158 F

Mechanical Test Specifications

Compression
10 N/mm,57 lb/in
Compression Test Method
FOTP-41,IEC 60794-1 E3
Flex
100 cycles
Flex Test Method
FOTP-104,IEC 60794-1 E6
Impact
4.34 ft lb,5.88 N-m
Impact Test Method
FOTP-25,IEC 60794-1 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP-33,IEC 60794-1 E1
Twist
10 cycles
Twist Test Method
FOTP-85,IEC 60794-1 E7

Environmental Test Specifications

Heat Age
-20 C to 85 C -4 F to 185 F
Heat Age Test Method
IEC 60794-1 F9
Low High Bend
-10 C to 60 C 14 F to 140 F
Low High Bend Test Method
FOTP-37,IEC 60794-1 E11
Temperature Cycle
-20 C to 70 C -4 F to 158 F
Temperature Cycle Test Method
FOTP-3,IEC 60794-1 F1