Каталог Корзина0
| Оптические кабели SYSTIMAX

760146563 Кабель оптический LazrSPEED 550, 6 волокон ОМ4, LSZH, универсальный, черный, гель, фут

Артикул: 760146563
Есть в наличии Цена по запросу Запросить цену Сравнить В сравнении

Доставка
при оплате сегодня (29.03.2024):

Москва:
— Самовывоз: завтра
— Курьером: 1 день

Регионы РФ
— ТК: 3-4 дня

Оплата
— Безналичный расчёт

Product Classification

Portfolio
CommScope
Product Type
Fiber drop cable
Regional Availability
Asia,Australia/New Zealand,EMEA,Latin America,North America

Standards And Qualifications

EN50575 CPR Cable EuroClass
Dca,s2,d1,a1
Cable Qualification Standards
ANSI/ICEA S-110-717,EN 187105,Telcordia GR-409

Representative Image

Click on image below to enlarge.

General Specifications

Cable Type
Riser rated low smoke
Construction Type
Non-armored
Subunit Type
Gel-filled

Construction Materials

Fiber Type Solution
OM4, LazrSPEED 550
Jacket Material
Low Smoke Zero Halogen LSZH
Total Fiber Count
6
Fiber Type
OM4, LazrSPEED 550
Fiber Type, quantity
6
Fibers per Subunit, quantity
6
Jacket Color
Black
Jacket UV Resistance
UV stabilized

Dimensions

Buffer Tube/Subunit Diameter
2.00 mm,0.08 in
Cable Weight
30.0 lb/kft,44.0 kg/km
Diameter Over Jacket
6.10 mm,0.24 in
Subunit, quantity
1

Physical Specifications

Minimum Bend Radius, loaded
9.1 cm,3.6 in
Minimum Bend Radius, unloaded
6.1 cm,2.4 in
Tensile Load, long term, maximum
400 N,90 lbf
Tensile Load, short term, maximum
1334 N,300 lbf
Vertical Rise, maximum
927.0 m,3041.3 ft

Flame Test Specifications

Flame Test Listing
NEC OFNR-LS ETL and c ETL
Flame Test Method
IEC 60332-3,IEC 60754-2,IEC 61034-2,IEEE 383,UL 1666,UL 1685

Environmental Specifications

Environmental Space
Aerial, lashed,Buried,Low Smoke Zero Halogen LSZH,Riser
Installation Temperature
-20 C to 60 C -4 F to 140 F
Operating Temperature
-20 C to 70 C -4 F to 158 F
Storage Temperature
-40 C to 75 C -40 F to 167 F

Mechanical Test Specifications

Compression
10 N/mm,57 lb/in
Compression Test Method
FOTP-41,IEC 60794-1 E3
Flex
35 cycles
Flex Test Method
FOTP-104,IEC 60794-1 E6
Impact
1.63 ft lb,2.21 N-m
Impact Test Method
FOTP-25,IEC 60794-1 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP-33,IEC 60794-1 E1
Twist
10 cycles
Twist Test Method
FOTP-85,IEC 60794-1 E7
Water Penentration
24 h
Water Penentration Test Method
FOTP-82,IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze
-2 C,28 F
Cable Freeze Test Method
FOTP-98,IEC 60794-1 F15
Drip
70 C,158 F
Drip Test Method
FOTP-81,IEC 60794-1 E14
Heat Age Test Method
IEC 60794-1 F9
Low High Bend
-20 C to 60 C -4 F to 140 F
Low High Bend Test Method
FOTP-37,IEC 60794-1 E11
Temperature Cycle
-20 C to 70 C -4 F to 158 F
Temperature Cycle Test Method
FOTP-3,IEC 60794-1 F1